Iron

As one of the most abundant elements, iron is ubiquitous in our daily lives. Iron salts are essential for human life and are absorbed through food and drinking water. However, excessive concentrations of iron in water are undesirable due to discoloration and the formation of deposits such as rust.
Our Iron Products

Products

Measuring range

Order

REF: 90725
Dipyridyl paper
Detection Limit: 2 mg/L Fe2+
$54.90
Pack size: 1 pack (200 test strips)
REF: 90726
Iron test paper
Detection Limit: 10 mg/L Fe2+ or Fe3+
$43.70
Pack size: 1 pack (100 test strips)
Rugged box with 20 test tubes. Sufficient for 20 tests.
REF: 985037
NANOCOLOR® Iron 3
Measuring range: 0.10 – 3.00 mg/L Fe
$70.20
Pack size: 1 pack (20 tube tests)
REF: 91359
QUANTOFIX® Iron Sensitive 1
Gradation: 0 · 0.05 · 0.2 · 0.5 · 1.0 mg/L Fe2+ 3+
$19.50
Pack size: 1 pack (25 test strips)
100 test strips in a tube, instruction leaflet
REF: 91344
QUANTOFIX® Total Iron 100
Gradation: 0 · 2 · 5 · 10 · 25 · 50 · 100 mg/L Fe2+ 3+
$37.00
Pack size: 1 pack (100 test strips without reagent)
100 test strips in a tube, instruction leaflet
REF: 91330
QUANTOFIX® Total Iron 1000
Gradation: 0 · 5 · 20 · 50 · 100 · 250 · 500 · 1000 mg/L Fe2+ 3+
$36.90
Pack size: 1 pack (100 test strips without reagent)
Rugged box with reagents for 250 tests.
REF: 91836
Standard test NANOCOLOR® Iron
Measuring range: Iron – 0.01-15.0 mg/L Fe
$166.00
Pack size: 1 pack (250 tests)
Rugged box with reagents for 250 tests.
REF: 918128
Standard test NANOCOLOR® Iron LR
Measuring range: Iron – 0.005-5.00 mg/L Fe
$177.00
Pack size: 1 pack (250 tests)
REF: 931025
VISOCOLOR® ECO Iron 1 Colorimetric test kit
Gradation: 0 · 0.04 · 0.07 · 0.10 · 0.15 · 0.20 · 0.30 · 0.50 · 1.0 mg/L Fe
$94.30
Pack size: 1 pack (reagents for 200 tests)
REF: 931026
VISOCOLOR® ECO Iron 2 Colorimetric test kit
Gradation: 0 · 0.04 · 0.07 · 0.10 · 0.15 · 0.20 · 0.30 · 0.50 · 1.0 mg/L Fe
$73.90
Pack size: 1 pack (reagents for 200 tests)
REF: 920040
VISOCOLOR® HE Iron Colorimetric test kit, for low concentrations
Gradation: 0.0 · 0.01 · 0.02 · 0.03 · 0.04 · 0.05 · 0.07 · 0.10 · 0.15 · 0.20 mg/L Fe
$159.00
Pack size: 1 pack (reagents for 300 tests)
100 Powder Pillows in a bag
REF: 936227
VISOCOLOR® Powder Pillows Iron, Photometric test, 100 tests
Instrumental measuring range: 0.03 – 3.00 mg/L Fe
$36.80
Pack size: 100 Powder Pillows
Reagents for 200 tests in a box
REF: 931225
VISOCOLOR® ECO Iron 1 Colorimetric test kit, Refill Pack
Gradation: 0 · 0.04 · 0.07 · 0.10 · 0.15 · 0.20 · 0.30 · 0.50 · 1.0 mg/L Fe
$78.10
Pack size: 1 pack (reagents for 200 tests)
Reagents for 100 tests in a box
REF: 931226
VISOCOLOR® ECO Iron 2 Colorimetric test kit, Refill Pack
Gradation: 0 · 0.04 · 0.07 · 0.10 · 0.15 · 0.20 · 0.30 · 0.50 · 1.0 mg/L Fe
$59.60
Pack size: 1 pack (reagents for 100 tests)
General information

With 6.2 %, iron is the 4th most abundant element in the earth’s crust and, after aluminum, the second most abundant metal. In water, it is present in various forms. Groundwaters with low oxygen levels and reducing medium often have iron contents of above 0.1 mg/L. The divalent iron(II) Fe2+ is particularly sensitive to air. It is oxidized by atmospheric oxygen to form trivalent iron(III) Fe3+, which precipitates as a brown, fuzzy-amorphous iron oxide hydrate due to its low solubility. Furthermore, the presence of iron is also pH-dependent. At pH values above 8, iron(II) ions Fe2+ are converted to poorly soluble iron(II) hydroxides.

Dissolved iron can limit the use of the water for consumers because precipitation can occur upon use of the water, for example in laundering. Iron in drinking water is undesirable because it leads to brown color and foul odor.

At the usually present concentrations, iron (and manganese) poses no direct health risk to humans. However, in drinking water these compounds are undesirable because they can form deposits in the pipe network that increase the flow resistance to a considerable extent. Consequences of this are firstly unwanted discolorations, on the other hand so-called secondary microbial contaminations due to corresponding iron and manganese bacteria.

The main application of iron is in the steel and metal industry. Due to its easy availability, strength and toughness, iron is one of the most important base materials. Iron is also used, amongst other things, as a flocculating agent. Determination of dissolved iron is an important indicator of the extent of corrosion.

Reagents for 300 tests, color chart and accessories in a box
Rugged box with 20 test tubes. Sufficient for 20 tests.
How to perform the NANOCOLOR Iron tube test
Reaction basis

All test kits are based on one of two different reaction principles:

(a) Triazine method:

Iron(II) ions react with a triazine derivative to form an intensely colored purple complex.

Triazine derivatives are highly miscible with thioglycolic acid. Thioglycolic acid is used for the
reduction of iron(III) to iron(II), and for pH adjustment. Thus only one reagent is required for analysis.

Test kits VISOCOLOR ECO Iron 1, VISOCOLOR ECO Iron 2, VISOCOLOR HE Iron, NANOCOLOR Iron 3, and NANOCOLOR Iron LR are based on this method.

Legend:
R = H, SO3H
irontubes

(b) DIN method analogous to APHA 3500-Fe D, DIN 38406-E1-1, ISO 633:

Iron(II) ions form an orange-colored complex compound with 1,10-phenanthroline. Iron(III) is reduced by a
suitable reducing agent to iron(II) and is also detected. A buffer adjusts the pH. This orange-red
phenanthroline complex is stable in the pH range of 2.5–9.

The described method detects dissolved iron and easily soluble iron compounds.

Following test kits are based on this method: VISOCOLOR Powder Pillows Iron, NANOCOLOR Iron, NANOCOLOR ECO Iron.

Legend:

Legend:

Distinction between total iron and dissolved iron

Dissolved iron comprises only the iron compounds present in the sample in completely dissolved form. Prior to analysis, filtration of the sample with the membrane filtration kit 0.45 µm is recommended.
For determination of total iron, decomposition with the reagent NANOCOLOR NanOx Metal or with the decomposition kit is required.

Legend:
Fe2+ can be discriminated from Fe3+ by omissing the reducing agent.
Differentiation of iron(III) and iron(II)

It is possible to distinguish between the two different oxidation states of iron in two tests: VISOCOLOR ECO Iron 2 and the standard test NANOCOLOR Iron.

Sample preservation
  • After adjusting the pH value to 1–2 with nitric acid, the sample can be preserved for storage for up to 1 month (storage vessel: PE or glass bottle).
  • After adjusting the pH value to 1-2 with hydrochloric acid 2, iron(II) compounds can be stored for up to 7 days.
Tips & tricks
  • Decomposition
    • For the simultaneous detection of iron complexes and determination of total iron, the sample must be oxidatively decomposed with NANOCOLOR NanOx Metal or the decomposition kit prior to analysis.
  • Background information
    • In the determination of iron in aqueous samples it must be noted that the previously mentioned processes will occur after sampling as well. Therefore, differentiated determination of forms present must be done directly on site. If this is not possible, the sample should be stabilized, if possible, by a few drops of acid (use depending on the parameters to be determined).
  • Filtration
    • To determine only “dissolved iron”, samples of turbid waters must be filtered prior to analysis.
  • Sea water suitability
    • Almost all VISOCOLOR and NANOCOLOR Iron tests are suitable for sea water analysis. The exception is the test VISOCOLOR HE Iron which does not allow sea water analysis. For more information, please refer to the respective instruction leaflet.
  • pH
    • The pH values which are stated in the instruction leaflets for the sample solution must be complied with. If necessary, adjust the pH with nitric acid or sodium hydroxide.
  • Interferences
    • Oxidants interfere with the determination in the test NANOCOLOR Iron 3.
    • Other metal ions such as cobalt or nickel disturb the test at various concentrations, depending on the test. The concentration from which on interference is to be expected is specified in the respective instruction leaflets.
    • Further interfering ions are listed in the instruction leaflets.
  • Turbidity
    • Turbid samples have to be filtered; turbidity leads to incorrect results: For coarsely dispersed turbidities, use qualitative filter paper (e.g. MN 615), for moderately dispersed turbidities, use glass-fiber paper (e.g. MN 85/70 BF) or membrane filtration set GF/PET 0.45 µm, for finely dispersed turbidities, use membrane filtration kit 0.45 µm or GF/PET 0.45 µm.